Welcome To b2b168.com, Join Free | Sign In
中文(简体) |
中文(繁體) |
Francés |Español |Deutsch |Pусский |
| No.13629353

- Product Categories
- Friendly Links
- home > Supply > Binzhou production and wholesale supply of prestressed pipe pressure slurry pulp factory direct pore pressure
Binzhou production and wholesale supply of prestressed pipe pressure slurry pulp factory direct pore pressure
Information Name: | Binzhou production and wholesale supply of prestressed pipe pressure slurry pulp factory direct pore pressure |
Published: | 2015-05-28 |
Validity: | 120 |
Specifications: | 40kg / Bag |
Quantity: | 10000.00 |
Price Description: | |
Detailed Product Description: | H-60B prestressed pipe pressure slurry This product is fully satisfied "JTG / T F50-2011" highway bridge construction technical specifications "," high performance prestressed pore filling material requirements. I. Applications 1, beam prestressed pipe grouting; 2, equipment foundation, bolt and other components grouting; 3, nuclear power plant housing grouting; ??? 4, loose concrete, repair cracks and holes and other defects. Second, the performance indicators Project performance test standard test method for water-cement ratio (%) 0.26 - 0.28 "cement standard consistency water, setting time and soundness test method" (GB / T 1346) setting time (h) the initial setting ≥5 Final setting ≤24 fluidity (25 ℃) (s) initial fluidity of 10 ~ 17 JTG / TF 50-2011 Appendix C3 30min 10 ~ 20 60min fluidity fluidity of 10 to 25 bleeding rate (%) 24h free bleeding rate 0 JTG / TF 50-2011 steel appendix C4 3h bleeding rate 0 JTG / TF 50-2011 Appendix C5 pressure bleeding rate (%) 0.22MPa (channel vertical height ≤1.8m) ≤2.0 JTG / TF 50-2011 Appendix C6 0.36MPa (channel vertical height> 1.8m) ≤2.0 free expansion rate (%) 3h 0 ~ 2 JTG / TF 50-2011 Appendix C4 24h 0 ~ 3 filling degree qualified JTG / TF 50-2011 Appendix C7 compressive strength (MPa ) 3d ≥20 "cement mortar strength test method (ISO method)" (GB / T 17671) 7d ≥40 28d ≥50 flexural strength (MPa) 3d ≥5 7d ≥6 28d ≥10 corrosion of the steel for non-corrosion "Concrete admixtures" (GB8076) Third, the construction method, the cement must be tested prior to use to determine the best ratio with, H-60B Recommended dosage is within the mixed 10.0%, water-cement ratio 0.26-0.28%. 2, mixing: Speed ??should not be less than 1000 rpm / min high-speed mechanical stirrer agitation at the following order: first the water was added to the appropriate scale, open mixer, a uniform grouting agent is added, and then even the cement; all the powder material into finished After stirring for another 3-5 minutes grouting 3, grouting: grouting soon as possible after mixing, grouting should take the usual methods. 4, clean: clean water for all the construction tools and equipment. 5. protection measures: the construction process to wear protective gloves and goggles. |
Admin>>>
You are the 19225 visitor
Copyright © GuangDong ICP No. 10089450, Beijing Warburg Vision Construction Co. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 19225 visitor
Copyright © GuangDong ICP No. 10089450, Beijing Warburg Vision Construction Co. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility